only products

Hoods

Accessories

Visit our Miele Online Boutique and purchase accessories online.
Active Filter
DKF 9-1Enlarge Image
DKF 9-1
Active charcoal filter for DA 249-4 and DA 44x-4 in recirculation mode.
In addition to the stainless steel metal filter which absorbs fat particles active charcoal filter are used for cooker hoods in recirculation mode.
Unpleasant kitchen odours are neutralized.
If you use your cooker hood in recirculation mode, ensure hood hour meter on. It reliably shows when the odour filter has to be changed to guarantee mode can work properly. For all cooker hoods, both recirculation and vented, the grease filter must be cleaned when the indicator lights up, which is usually the case every 3-4 weeks.
For more details about optimal cleaning and care, please refer to the operating manual.
The filters should be regularly cleaned or changed as appropriate. Saturated filters can be a fire hazard.
DKF 11-1Enlarge Image
DKF 11-1
Active charcoal filter for DA 5990 W in recirculation mode.
In addition to the stainless steel metal filter which absorbs fat particles active charcoal filter are used for cooker hoods in recirculation mode.
Unpleasant kitchen odours are neutralized.
If you use your cooker hood in recirculation mode, ensure hood hour meter on. It reliably shows when the odour filter has to be changed to guarantee mode can work properly. For all cooker hoods, both recirculation and vented, the grease filter must be cleaned when the indicator lights up, which is usually the case every 3-4 weeks.
For more details about optimal cleaning and care, please refer to the operating manual.
The filters should be regularly cleaned or changed as appropriate. Saturated filters can be a fire hazard.
DKF 12-1Enlarge Image
DKF 12-1
Active charcoal filter for DA 146, DA 15x, DA 186, DA 249-4, DA 2xxx and DA 3xxx in recirculation mode.
In addition to the stainless steel metal filter which absorbs fat particles active charcoal filter are used for cooker hoods in recirculation mode.
Unpleasant kitchen odours are neutralized.
If you use your cooker hood in recirculation mode, ensure hood hour meter on. It reliably shows when the odour filter has to be changed to guarantee mode can work properly. For all cooker hoods, both recirculation and vented, the grease filter must be cleaned when the indicator lights up, which is usually the case every 3-4 weeks.
For more details about optimal cleaning and care, please refer to the operating manual.
The filters should be regularly cleaned or changed as appropriate. Saturated filters can be a fire hazard.
DKF 13-1Enlarge Image
DKF 13-1
Active charcoal filter for DA 3xxx in recirculation mode.
In addition to the stainless steel metal filter which absorbs fat particles active charcoal filter are used for cooker hoods in recirculation mode.
Unpleasant kitchen odours are neutralized.
If you use your cooker hood in recirculation mode, ensure hood hour meter on. It reliably shows when the odour filter has to be changed to guarantee mode can work properly. For all cooker hoods, both recirculation and vented, the grease filter must be cleaned when the indicator lights up, which is usually the case every 3-4 weeks.
For more details about optimal cleaning and care, please refer to the operating manual.
The filters should be regularly cleaned or changed as appropriate. Saturated filters can be a fire hazard.
DKF 15-1Enlarge Image
DKF 15-1
Active charcoal filter for DA 2xxx in recirculation mode.
In addition to the stainless steel metal filter which absorbs fat particles active charcoal filter are used for cooker hoods in recirculation mode.
Unpleasant kitchen odours are neutralized.
If you use your cooker hood in recirculation mode, ensure hood hour meter on. It reliably shows when the odour filter has to be changed to guarantee mode can work properly. For all cooker hoods, both recirculation and vented, the grease filter must be cleaned when the indicator lights up, which is usually the case every 3-4 weeks.
For more details about optimal cleaning and care, please refer to the operating manual.
The filters should be regularly cleaned or changed as appropriate. Saturated filters can be a fire hazard.
DKF 16-1Enlarge Image
DKF 16-1
Charcoal filter for use in DA 7090 W.
Contents: 2 filters
In addition to the stainless steel metal filter which absorbs fat particles active charcoal filter are used for cooker hoods in recirculation mode.
Unpleasant kitchen odours are neutralized.
If you use your cooker hood in recirculation mode, ensure hood hour meter on. It reliably shows when the odour filter has to be changed to guarantee mode can work properly. For all cooker hoods, both recirculation and vented, the grease filter must be cleaned when the indicator lights up, which is usually the case every 3-4 weeks.
For more details about optimal cleaning and care, please refer to the operating manual.
The filters should be regularly cleaned or changed as appropriate. Saturated filters can be a fire hazard.
DKF 17-1Enlarge Image
DKF 17-1
Charcoal filter for use in DA 7000 D.
Contents: 4 filters
In addition to the stainless steel metal filter which absorbs fat particles active charcoal filter are used for cooker hoods in recirculation mode.
Unpleasant kitchen odours are neutralized.
If you use your cooker hood in recirculation mode, ensure hood hour meter on. It reliably shows when the odour filter has to be changed to guarantee mode can work properly. For all cooker hoods, both recirculation and vented, the grease filter must be cleaned when the indicator lights up, which is usually the case every 3-4 weeks.
For more details about optimal cleaning and care, please refer to the operating manual.
The filters should be regularly cleaned or changed as appropriate. Saturated filters can be a fire hazard.
Décor Element
DDWEnlarge Image
DDW
Décor elements for wall-mounted DA 5320 W and DA 5390 W.
To optically enhance the filter area 4 décor elements can be fitted to the DA 5320 W and 3 décor elements to the DA 5390 W.
DDI 5320Enlarge Image
DDI 5320
Set of stainless steel decor elements for DA 5320 D
To optically enhance the filter area 4 decor elements can be fitted to this island cooker hood.
DDI 5330Enlarge Image
DDI 5330
Set of stainless steel decor elements for DA 5330 D
To optically enhance the filter area 6 decor elements can be fitted to
this island cooker hood
Conversion kit
DUI 31Enlarge Image
DUI 31
Suitable for DA 420 / DA 424 V
Must be supplied with relevant active charcoal filter.
DUU 151Enlarge Image
DUU 151
For converting from extraction to recirculation mode
Supplied with ventilation grille, hose clip and ducting which extends to 70 cm
Suitable for DA 3160/3190/2170
DUW 20Enlarge Image
DUW 20
Conversion kit from vented to recirculation.
Suitable for DA 396, DA 399, DA 406, DA 407, DA 409, DA 439
External motor
ABLG 202Enlarge Image
ABLG 202

Installation

For installation in an internal location, e.g. in a loft

Features

Stainless steel casing, double sided radial fan,ducting connection 125/150 mm diameter

Extraction rate

Extraction = 280-900 m³/h, unrestricted

Accessories

Control cable, 500 cm long, with plug connectors

Optional accessories

Additional control cables

Planning tips:

When planning the position of the cooker hood make sure that there is at
least 5-7 meters between the cooker hood and the external motor.
AWG 102Enlarge Image
AWG 102

Installation

For installation on an external wall

Features

Stainless steel casing

Extraction rate

Extraction = 440-1000 m³/h, unrestricted

Accessories

Telescopic wall pipe, 180 mm Ø (extends up to 45 cm)
Control cable, 500 cm long, with plug connectors
Stainless steel cladding

Optional accessories

Additional control cables

Planning tips:

When planning the position of the cooker hood make sure that there is at
least 5-7 meters between the cooker hood and the external motor.
Can withstand temperatures of up to -20°C
DDG 102Enlarge Image
DDG 102

Installation

For installation on a tiled roof with an angle of at least 10°
Not suitable for use on flat roofs

Features

Stainless steel casing with skirt
Single sided radial fan
Control cable with plug connectors for linking the external motor to the cooker hood
Ducting diameter 125/150 mm

Extraction rate

Extraction = 440-1000 m3/h. Unrestricted (820 m3/h in practice),
[measurements taken under installation conditions as follows: Cooker hood, one 90° angle, 4 m ducting between cooker hood and external motor]

Accessories

Additional control cable, 500 cm long, with plug connectors

Optional accessories

Additional control cables

Note:

Suitable for temperatures up to -20°C.
MG 100Enlarge Image
MG 100

Installation

For installation on an outside wall using a telescopic wall kit

Features

Powder coated casing
Single sided radial fan
Stainless steel front
Ducting diameter 150 mm

Extraction rate

Extraction = 310-850 m³/hr, unrestricted
In praxis approx 730 m³/hr
(Measured with 90° elbow and 4 m duction to the external motor)

Accessories

Additional control cable, 300 cm long, with plug connectors

Optional accessories

Additional control cables

Note:

Suitable for temperatures up to -20°C.
Vent duct
DAS 150Enlarge Image
DAS 150
Vent hose, flexible, 150 mm diameter, 5 m length
DAS 200
Vent duct 200 mm
Roof Vent
DDF 125/150Enlarge Image
DDF 125/150

Features

Stainless steel casing with frame
Ducting outlet faces downwards
Non-return flap
Ø 125 cm

Installation

For extraction and ventilation. Suitable for all roof angles and tiles.
Not suitable for use on flat roofs.

Accessories

Roof vent kit Ø 125 cm
DDF 200Enlarge Image
DDF 200

Installation

For extraction and ventilation. Suitable for all roof angles and tiles.
Not suitable for use on flat roofs.

Features

Stainless steel casing with lead collar
Ducting outlet faces downwards
Non-return flap
Ducting diameter 200 mm
Silencer
DSAD 150Enlarge Image
DSAD 150
For additional noise deduction when using external motors. The DASD 150
is 250 mm long and is equipped with a 150 mm plug connectors

N.B. Not suitable for recirculation for DA 249-4/ 270-4/ 420 U/ 420 V/ 5100 DU

Reducer
Reducer (150mm - 125mm)
Reducer for 150 mm to 125 mm diameter
Reducer (200mm - 150mm)
Reducer for 200 mm to 150 mm diameter
Other Accessories
DASDV 150Enlarge Image
DASDV 150
Connecting element for 2 DASD 150
DER 6000Enlarge Image
DER 6000
For installation of DA 6000 W wall decor hood and positioning and adjustment of canopy.
DFG 200Enlarge Image
DFG 200
Wall air extraction grill in stainless steel (200 mm diameter)
DSM 400Enlarge Image
DSM 400
For cooker hoods (except DA 1xx/20xx/6000 W)
For use with:
– Window contact switch
– Separate light switch
– Potential free contact for connecting to external
appliances with their own power supply e.g. air intake fan 230 V AC/2 (1) A
Installation:
DSM 400 and the window contact switch should be connected to the cooker hood by a suitably qualified person. Other functions provided by the DSM 400 require the services of an electrician.
* For DA 289-4/489-4: please order mounting bracket at the same time
DDB 150Enlarge Image
DDB 150
For the installation of island hoods in combination with suspended ceilings. Accommodates height differences of 110 - 300 mm between concrete ceiling and suspended ceiling. Suitable for all island decor hoods with 150 mm Ø connector.
 Back to toptop